Product Description
High Precision, Robust Design, Durable: the Panel-Mount Peakmeters 40 x 190
These RTW peak program meters in standard broadcasting cassettes (40 x 190 mm) feature high precision, robust design and long-lived electronics that don’t need adjustment for demanding applications in studios, broadcasting, network control rooms, outside broadcasting units, analog and digital mastering. All units use reliable gas plasma displays (neon orange), guaranteeing excellent legibility even under poor lighting and outstanding precision thanks to the very high resolution (201 segments per channel).
The panel-mount peak program meters are available in five basic versions with different instrumentation and with customary standards (Digital and DIN, ARD+9).
Discontinued models: All panel-mount peakmeter 40 x 190 mm (except 1119G and 11528G) can only be ordered until June 30th, 2012!
Features
- Panel-mount units in metal cassettes with standard dimensions: 40 x 190 mm, 107 mm depth
- High-resolution, 201-segment gas plasma display, scale length 127 mm
- Sandwich scale for horizontal or vertical installation
- All models conform to the applicable standards (IRT 3/6, DIN 45406)
Additional features of the analog instruments:
- Power supply 24 V, +/-15 V DC
- Standard 32-pin DIN 41612/C connector
- Transformer-balanced inputs (except 1113G: electronically balanced)
- Input sensitivity +6 dBu
- Measurement range -50 dB to +5 dB (DIN versions)
Additional features of the digital instruments:
- Power supply 22–30 V DC
- Standard 64-pin DIN 41612/C connector
- Transformer-balanced AES/EBU input, input signals actively buffered
- Digital scale -60 dB FS to 0 dB FS, also DIN scale or [ARD+9]
- User-adjustable headroom markers
- Sampling rates 27 kHz to 96 kHz
- Overload display with adjustable sensitivity and attack time
- Peak hold display
Models
Models
DIN Standard
Analog inputs (transformer balanced, except 1113G), DIN scale (-50 to +5 dB, reference level +6 dBu at 0 dB mark, overload range 0 to 5 dB), integration time 10 ms, 201 segments gas plasma displays
1113G - only available until June 30th, 2012 -
2-ch. peakmeter with electronically balanced inputs
1119G
2-ch. peakmeter, peak memory, 20 dB gain, Fast mode (1 ms), phase meter
1019GL - only available until June 30th, 2012 -
2-ch. peakmeter, peak memory, 20 dB gain, Fast mode (1 ms), phase meter, peak hold, loudness
DIGITAL Standard
Digital AES/EBU inputs (transformer balanced), digital outputs, sampling rates 27 to 96 kHz, Digital scale (-60 to 0 dB FS, selectable headroom, preset to -9 dB FS), overload indicators, integration time sample, 201 segments gas plasma displays
11519G - only available until June 30th, 2012 -
2-ch. peakmeter, peak memory, 40 dB gain, phase meter
11519G-DIN - only available until June 30th, 2012 -
same as 11519G, but with quasi-DIN scale (-50 to +5 dB, -9 dB FS digital level adjusted to 0 dB mark), integration time 10 ms, 20 dB gain
11529G - only available until June 30th, 2012 -
2-ch. peakmeter, peak memory, 40 dB gain, phase meter, peak hold, loudness
11529G-DIN - only available until June 30th, 2012 -
same as 11529G, but with quasi-DIN scale (-50 to +5 dB, -9 dB FS digital level adjusted to 0 dB mark), integration time 10 ms, 20 dB gain
DIGITAL Special Version for broadcast applications [ARD+9]
11528G
Digital AES/EBU inputs (transformer balanced), digital outputs, sampling rates 27 to 96 kHz, measuring range -60 to 0 dB FS, scale range -60 to +9 dB, fixed headroom (-9 dB FS at 0 dB mark), double indication: peak level (0 ms) with either peak level (10 ms) or RTW loudness, overload indicators, integration time sample, 201 segments gas plasma displays, peak memory, 40 dB gain, phase meter, loudness
Accessories
Accessories
1020E
Table-top housing with power supply and connectors, for analog 40 x 190 mm instruments: XLR input connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
10220
Table-top housing with power supply and connectors, for digital 40 x 190 mm instruments: XLR input and output connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
1128H
Power pack and bracket for mounting to 19“/1U rack-mount kits, enables the mounting of analog 40 x 190 mm instruments into 19“ environments: XLR input connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
11280
Power pack and bracket for mounting to 19“/1U rack-mount kits, enables the mounting of digital 40 x 190 mm instruments into 19“ environments: XLR input and output connectors, Sub-D remote connector, switches, 115/230 V AC power supply, switchable
12993
19“/1U rack-mount kit, black, for one 40 x 190 mm instrument
12994
19“/1U rack-mount kit, black, for two 40 x 190 mm instruments
12996
Cover plate and mounting frame for 40 x 190 mm instruments, overall dimensions 210 x 60 mm
13973 - only available until June 30th, 2012 -
Clamping lock fastening kit for retrofitting 40 x 190 mm standard panel mount cassette instruments